Products


Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
+
  • Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
  • Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
  • Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
  • Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
  • Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables
  • Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables

Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables


Category: UL Series

1. Single or stranded conductor, PVC insulated single core wire 2. Rated temperature: 105 ℃ 3. Rated voltage: 1000v ac/1250v dc 4. Product standard: UL758/UL1581 5. Core number range: 1, cross-sectional area range: 30AWG-2000Kcmil 6. Pass VW-1 and CSA FT1 vertical flame retardant test 7. Purpose: can be used for photovoltaic inverter and energy storage system connection line


E-mail:oversea@hichain.com.cn

Product Description

 

1. Single or stranded conductor, PVC insulated single core wire
2. Rated temperature: 105 ℃
3. Rated voltage: 1000v ac/1250v dc
4. Product standard: UL758/UL1581
5. Core number range: 1, cross-sectional area range: 30AWG-2000Kcmil
6. Pass VW-1 and CSA FT1 vertical flame retardant test
7. Purpose: can be used for photovoltaic inverter and energy storage system connection line

 

Product Specifications

 

Line Number

conductor structure(n/mm)

Outer diameter of conductor bundle (mm)
REF reference value 
 

Minimum average thickness(mm)

Minimum insulation thickness(mm)

Cable outer diameter(mm)

Maximum conductor resistance(Ώ/KM)

28

7/0.127

0.38 

0.76 

0.69

2.00±0.10

239

26

7/0.16

0.48 

0.76 

0.69

2.10±0.10

150

24

11/0.16

0.61 

0.76 

0.69

2.20±0.10

94.20 

22

17/0.16

0.76 

0.76 

0.69

2.35±0.15

59.40 

20

26/0.16

0.93 

0.76 

0.69

2.60±0.15

36.70 

18

41/0.16

1.18 

0.76 

0.69

2.80±0.15

23.20 

17

52/0.16

1.33 

0.76 

0.69

2.95±0.15

18.30 

16

26/0.254

1.49 

0.76 

0.69

3.10±0.15

14.60 

14

41/0.254

1.88 

0.76 

0.69

3.60±0.15

8.960 

13

52/0.254

2.11 

0.76 

0.69

3.70±0.15

7.100 

12

65/0.254

2.36 

0.76 

0.69

4.00±0.15

5.640 

11

83/0.254

2.67 

0.76 

0.69 

4.30±0.15

4.480 

10

105/0.254

3.02 

0.76 

0.69

4.70±0.20

3.546 

9

133/0.254

3.40 

0.76 

0.69

5.10±0.20

2.813 

8

168/0.254

3.80 

1.14 

1.04

6.30±0.25

2.230 

7

210/0.254

4.25 

1.14 

1.04

6.70±0.25

1.768 

6

266/0.254

4.80 

1.52 

1.37

8.00±0.25

1.403 

5

336/0.254

6.10 

1.52 

1.37

9.20±0.25

1.113 

4

420/0.254

6.82 

1.52 

1.37

10.00±0.30

0.882 

3

532/0.254

7.47 

1.52 

1.37

10.50±0.30

0.6996

2

665/0.254

8.58 

1.52 

1.37

11.80±0.40

0.5548

1

836/0.254

9.43 

2.03 

1.83

13.50±0.40

0.4398

1/0

1045/0.254

10.58 

2.03 

1.83

14.70±0.50

0.3487

2/0

342/0.50

12.25 

2.03 

1.83

16.60±0.50

0.2766

3/0

418/0.51

13.81 

2.03 

1.83

18.00±0.50

0.2194

4/0

525/0.51

15.31 

2.03 

1.83

19.80±0.50

0.1722

250kcmil

646/0.50

16.84 

2.42 

2.18

22.10±0.50

0.1473

300kcmil

740/0.51

18.44 

2.42 

2.18

23.80±0.50

0.1227

350kcmil

888/0.51

20.20 

2.42 

2.18

25.50±0.60

0.1052

400kcmil

999/0.51

21.43 

2.42 

2.18

28.00±0.60

0.09109

Keywords: Power Cables UL10269 Photovoltaic Solar Cables New Energy Cables Battery Cables