Information
Essential Knowledge for Wire and Cable Inspection — Measurement of Braiding Density
Release time: 2026-09-24
I. Purpose of Inspection
In cable construction, the metallic braided shield serves as both an outer conductor and a shielding layer in coaxial cables, while in ordinary power and control cables it provides uniform electric field distribution and electromagnetic interference (EMI) protection. The braiding density directly affects the shielding performance of the product; therefore, technical specifications for such products stipulate a minimum braiding density. A higher braiding density yields better shielding, whereas a lower density results in poorer shielding. Consequently, the primary purpose of measuring braiding density is to verify that the braiding (or wrapping) density meets the values specified in the relevant standards.
II. Scope of Application
Suitable for shielded wires and cables.
III. Basis for Inspection
Relevant product standards.
IV. Test Equipment and Instruments
1. Outside micrometer, caliper, steel ruler.
2. Pencil, paper tape.
V. Sampling and Specimen Preparation Equipment
1. Cable test samples shall be taken at three locations, each spaced at least 1 meter apart.
2. Remove all components from the woven surface without causing any damage.
VI. Test Procedure
1. Visually estimate the knitting gauge (m) and the number of single yarns per spindle (n).
2. Measuring the braid pitch (l) using the paper‑tape method: First, lay a strip of paper of appropriate width and approximately twice the pitch in length flat on the braid being measured. Then, use a pencil to rub along the axis of the braid (the rubbing length should exceed one pitch), leaving a series of fiber‑trace marks on the paper that correspond to more than half the number of plies. Use a steel ruler to measure the distance between the marks corresponding to half the number of plies; this distance represents the measured pitch. Take the average of at least three measurements as the braid pitch for the specimen.
3. Measurement of the outer diameter (D) of the braided layer.
Use a dial caliper or an outside micrometer to take one measurement in each of two mutually perpendicular directions on the same cross-section (ensure that the measuring instrument is perpendicular to the product’s axis and minimize the contact pressure exerted by the instrument on the part being measured). Then, divide the average of the two measurements by the number of measurements taken; the resulting value is the outer diameter at that point.
4. Measure the single-wire diameter (d) using an outside micrometer.
5. Calculate the weaving (or winding) density of the braided layer.
The calculation formula is as follows:
Kf = (mnd/2l)[1 + (l/πD)²]¹/²
K = (2Kf - Kf²) × 100%
In the equation: kf — unidirectional coverage coefficient;
k — knitting density, %
l — pitch, mm;
d — Diameter of the metallic round single wire used for shielding, mm;
D — Shielding layer diameter, mm;
m — total number of spindles;
n — Number of strands per bobbin.
VII. Evaluation of Test Results
The shielding density shall comply with the relevant standards. For single‑core shielded wires with a nominal cross‑section of 0.12 mm² or less, the braid density of the shield shall be no less than 60%; for other shielded wires, the shielding density shall be no less than 80%. Specific requirements shall be in accordance with the applicable manufacturing standards.