Information
Analysis of New Energy Vehicle Charging Gun Lines - DC
Release time: 2025-06-17
The DC charging gun cable is a key component for fast charging of electric vehicles. Its cable design must meet the requirements of high-power transmission, safety, and durability. The following is a detailed analysis of its cable structure:

1. Conductor Material
- High-purity copper Using multiple strands of fine copper wire twisted together to improve flexibility and conductivity.
- Cross-sectional area Usually 35mm²~120mm² For example, 250A If the current needs 70mm² It is adjusted according to the charging power (e.g.,). 60kW/150kW/350kW)调整。
- Plating treatment Some may be tin-plated to prevent oxidation.
2. Insulation layer
- Material Cross-linked polyethylene ( XLPE ) or silicone rubber, high temperature resistant ( -40 ℃ ~125 ℃ ), high voltage resistant ( 1000V and above) and flame retardant.
- Color distinction Positive pole (red), negative pole (black), and signal line (other colors).
3. Shielding layer
- Double shielding :
- Aluminum foil shielding Resistant to high-frequency interference.
- Copper mesh braided shielding (Coverage ≥80% ): Resisting low-frequency electromagnetic interference to ensure stable communication.
- Ground wire Integrated into the shielding layer to drain stray current.
4. Cooling design (high-power gun line)
- Liquid cooling channel Some supercharging gun lines have built-in coolant pipes to reduce temperature rise.
- Hollow conductor A few designs use hollow conductors to circulate cooling media.
5. Outer sheath
- Wear-resistant material Polyurethane ( PUR ) or chloroprene rubber ( CR ), resistant to mechanical stress, oil stains, and ultraviolet rays.
- Flexibility Optimized structural design to adapt to frequent bending (e.g., IP67 Protection level).
6. Signal and control lines
- CAN Bus /PLC Communication line Used for communication between the charging pile and the vehicle BMS Communication (such as charging protocol handshake, power adjustment).
- Low-voltage harness Including temperature sensor lines (real-time monitoring of connector temperature), interlock signal lines, etc.
7. Key performance parameters
- Current carrying capacity Common 200A~500A (Liquid-cooled gun lines can reach 600A and above).
- Voltage level :400V (mainstream) or 800V。
- Charging speed :30 Charged to within minutes 80% For example, 350kW Supercharging).
8. Safety design
- Temperature monitoring : NTC Thermistor provides real-time feedback of overheating signals.
- Interlock circuit Checks the integrity of the interface before charging and cuts off the power in case of abnormality.
- High-voltage interlock ( HVIL ) Prevents live plugging and unplugging.
9. Typical standards
- International : IEC 62196-3 、 CCS ( Combo ), CHAdeMO 。
- Domestic : GB/T 20234.3-2015 (DC charging interface).
10. Common failure points
- Conductor oxidation Long-term use leads to increased contact resistance.
- Sheath cracking Caused by frequent bending or low-temperature hardening.
- Shielding failure Communication is affected by electromagnetic interference.
Summary
DC charging gun cables combine high voltage, high current, and precise control. Their design must balance electrical efficiency, thermal management, and mechanical strength. With the development of ultra-fast charging technology, liquid cooling and high-voltage platforms ( 800V and above) will become future trends.
oversea@hichain.com.cn